Vicon V992-N Guía de instalación

Busca en linea o descarga Guía de instalación para Cámaras De Seguridad Vicon V992-N. Vicon V992-N Installation guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 31
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
www.vicon-security.com
XX248-00-00
V992-N Network
Camera
Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the
operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed
to be used in life-critical situations and must not be used for this purpose.
Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788
Tel: 631-952-2288 Fax: 631-951-2288 Toll Free: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300
Document Number: 8009-8248-00-00
Product specications subject to change without notice.
Issued: 512
Copyright © 2011 Vicon Industries Inc. All rights reserved.
Installation Guide
Vista de pagina 0
1 2 3 4 5 6 ... 30 31

Indice de contenidos

Pagina 1 - V992-N Network

www.vicon-security.com XX248-00-00V992-N Network CameraVicon Industries Inc. does not warrant that the f

Pagina 2 - Contents

8 4.1.1 Installation Setup Installation Mode allows use of the analog BNC output from the camera to connect the camera NTSC, PAL: Analog Output is

Pagina 3 - 1. Product Features

9 bandwidth usage to be controlled. CBR (Constant Bit Rate) is used to achieve a specific bit rate by varying the quality of the H.264 stream. While

Pagina 4 - 2. Installation

10 < Output resolution and Frame rate table for V992-N > (Unit: fps) RESOLUTION Table Second Stream 720p 4CIF 4CIF* VGA 4:3 VGA 16:9

Pagina 5 - 2.3 Access from a browser

11 To compensate for poor lighting conditions, you can adjust the Color level, Brightness, Sharpness, Contrast and Exposure control. NOTE: When AE is

Pagina 6

12 4.3 Live V992-N can support up to 10 simultaneous users via unicast. 4.3.1 Viewer Setup Live View Protocol RTP Unicast (UDP)/RTP over

Pagina 7 - 3. Live View

13 4.4.FTP 4.4.1 Config Server Configuration Allows transmission of still images to remote sites using the FTP server. Set the information

Pagina 8 - 3.2 How to Stream H.264

14 File Prefix You may add a file name prefix to the stored image file name. Example: If the file prefix is ‘MVD’, the still image would be saved

Pagina 9 - 4. Setup

15 Effective Period This parameter lets you decide whether to save still images at all hours of the day, or during specific times of the day.

Pagina 10 - 4.2.1 Codec

16 4.5.2 Mapping Event Mapping It is possible to define conditions that would cause the camera to respond with certain actions. A triggered event

Pagina 11

17 DNS Configuration DNS (Domain Name Server) provides the translation of host names to IP addresses on your network. Primary DNS server Enter

Pagina 12 - 4.2.2 Camera

Contents 1. PRODUCT FEATURES ...

Pagina 13

18 4.6.2 Service Port Service Port HTTP port The default HTTP port number (80) could be changed to any port within the valid port range (1-65535)

Pagina 14 - 4.3.1 Viewer Setup

19 4.6.3 E-mail You must turn Notification to ‘On’ and then enter the host names or addresses for your mail servers in the fields provided to enable

Pagina 15 - 4.4.1 Config

20 4.7 System 4.7.1 User When you access the camera, the Configure Root Password dialog box appears. Enter the default user name ADMIN and pass

Pagina 16 - 4.4.3 Periodical

21 NTP Server Synchronize the time from an NTP server every 60 minutes. Specify the IP address or host name of the NTP server you are using. Local

Pagina 17 - 4.5.1 Motion

22 Firmware Update Procedure 1. Save the firmware file to your computer. 2. Go to Setup > System > Maintenance within the camera web browse

Pagina 18 - 4.6.1 IP Setup

23 4.7.4 Information System Information Confirm the system information of the camera: S/W version/Model Name/MAC address/IP address settings.

Pagina 22 - 4.7.2 Date/Time

27 Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.)

Pagina 23 - 4.7.3 Maintenance

1 1. Product Features The V992-N is a high performance H.264 network camera, designed for demanding security installations. It delivers crisp, clear

Pagina 24 - Factory Default Reset

28 Vicon Standard Equipment Warranty Vicon Industries Inc. (the “Company”) warrants your equipment to be free from defects in material and workmans

Pagina 25 - 4.7.4 Information

Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-2288 800-645-9116 Fax: 631-951-2288 Vic

Pagina 26 - 5. Dimensions

2 2. Installation 2.1 Install camera 1) Assemble the mounting tripod (supplied), used when mounting the camera to a wall bracket, onto camera wit

Pagina 27

3 3) Select the “Change IP Address” button. The message “Do you want to change IP address?” will display; select “Yes” from the pop-up window. 4) C

Pagina 28

4 When you first access the camera you will be asked to download and install an Active X control from the camera to display a Live image.

Pagina 29 - Shipping Instructions

5 With Web Browser 1. Open the Live View page in your web browser. - Select the Setup tab, and open the Video -> Camera page. - Cl

Pagina 30

6 3.1 Video Stream Types Motion JPEG This format uses standard JPEG images in the video stream. These images are then displayed and updated at a r

Pagina 31 - Vicon Industries Inc

7 may cause congestion. Although there is a maximum of 10 unicast viewers, note that all multicast users combined count as 1 unicast viewer. RTP/RT

Comentarios a estos manuales

Sin comentarios