Cable Recommendations
RS-422 Protocol
For all RS-422 protocol connections terminated in open wires or onto D-shell type connector use a 2-
conductor (twisted pair) shielded copper wire to make the connections. Refer to Table 1, Shielded, Dual
Twisted-Pair Cable Maximum Operating Distances.
For all RS-422 protocol connections
terminated in RJ-45 type (8 conductor)
cable, use a cable that does not exceed
6 ft (15 m). For wire runs longer than
this, use RJ-45 Termination Boxes
locally and longer runs with shielded
twisted-pair-cables in accordance with
Table 1.
Manual References for Associated Equipment
CPUs
V1200X V1200X Series Transmitter/CPU X379
V1300X Microprocessor-Based Control System X553
VPS328/V1422 VPS328/V1422 Digital Control, Installation/Operation X826
Input Devices
V1300X-DVC/RVC Intelligent Remote Control Panels X777
V1400X-DVC System Console XX090
Output Devices
V1200R-LM Multiple Receiver X512
V1301R Outdoor Receiver X506
V1311RB Universal Receiver X871
V1319R Dual Station Receiver X825
V15UVS Omniscan Dome X806
V7UVS Surveyor Mini Dome X971
V5UVS Surveyor 99 Dome X978
SUR2000 Surveyor2000 Mini-Dome XX031
CABLE TYPE
DISTANCE ft
m
max. NUMBER REQUIRED
Belden 9406 5000
1500
1
Belden 9402 5000
1500
1
Belden 8723 8000
2400
1
Belden 8162 15000
4600
1
Belden 9729 15000
4600
1
Belden 9182
25000 (7600)
2
Table 1
Shielded, Dual Twisted-Pair Cable
Maximum Operating Distances