Vicon SVFT-W23C Especificaciones

Busca en linea o descarga Especificaciones para Cámaras De Seguridad Vicon SVFT-W23C. Vicon SVFT-W23C Product specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 82
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Vicon part number 8009-8134-08-01 Section 3 Rev 209
XX134-08-01
Camera Dome
Warning: To reduce a risk of fire or electric shock, do not expose
the indoor unit to rain or moisture.
Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your
requirements or that the operation will be entirely error free or perform precisely as described in the
documentation. This system has not been designed to be used in life-critical situations and must not be
used for this purpose.
Copyright © 2009 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
SurveyorVFT, NOVA and Vicoax are trademarks and ViconNet and Kollector are registered trademarks of Vicon Industries Inc.
ExView is a trademark of Sony Corporation.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300 WEB: www.vicon-cctv.com
Vista de pagina 0
1 2 3 4 5 6 ... 81 82

Indice de contenidos

Pagina 1 - Camera Dome

Vicon part number 8009-8134-08-01 Section 3 Rev 209 XX134-08-01 Camera Dome

Pagina 2

Table 1 Models and Descriptions Model Number Product Code Environment/ Cable Type Camera Type/Format Mount Type Optical Zoom/ Total Zoom Lower Dome

Pagina 3 - GRAPHIC SYMBOL EXPLANATION

Power Table Power* (W) Current Rating (A) Model Number Coax, UTP, Fiber ViconNet Coax, UTP, Fiber ViconNet SVFT-C22/ SVFT-C22C 24 34 1.0 1.4 SVF

Pagina 4

How to Use this Manual This manual was designed to provide the best overall instructions for the installation and operation of the SurveyorVFT Camera

Pagina 5 - FCC Notice

Accessory Kits There are 3 different accessory kits included with the different configurations of SurveyorVFT; Standard/Fiber-Optic Option, Twisted P

Pagina 6

Unpacking the SurveyorVFT In-Ceiling Unpacking the SurveyorVFT Indoor Pendant 6 • 3BIntroduction XX134-08-01 Rev 209 SurveyorVFT Camera Dome

Pagina 7 - Contents

Unpacking the SurveyorVFT Outdoor Pendant XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 3BIntroduction • 7

Pagina 8

SurveyorVFT Components All SurveyorVFT units are comprised of an Enclosure/Housing, a Camera Drive, a Shroud and a Lower Dome. Figures 1, 2 and 3 sho

Pagina 9 - Introduction

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 3BIntroduction • 9 Figure 3 SurveyorVFT Outdoor Pendant Figure 2 SurveyorVFT Indoor Pendant

Pagina 10

10 • 3BIntroduction XX134-08-01 Rev 209 SurveyorVFT Camera Dome System

Pagina 11 - *Power @ 24 VAC

Installation Choose the installation type based on the specific unit purchased (In-Ceiling, Indoor or Outdoor Pendant). Quick Installation – In-Ceili

Pagina 13 - Unpacking and Inspection

Quick Installation – Indoor Pendant Q U I C K I N S T A L L A T I O N QUICKINSTALLATION 12 • 4BInstallation XX134-08-01 Rev 209 SurveyorVF

Pagina 14

Quick Installation – Outdoor Pendant QUICKINSTALLATION Q U I C K I N S T A L L A T I O N XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 4

Pagina 15

Detailed Installation These steps provide the most thorough and accurate instructions. In-Ceiling Mount Model This version of SurveyorVFT mounts in t

Pagina 16 - SurveyorVFT Components

The accessory kit contains the removable screw terminal blocks to be used for all connections in this installation. Figure 6 Unlatching the Custome

Pagina 17

Note: There should be minimal wire slack at all connection points. a) Strip approximately 1 inch (25 mm) of cable outer jacket to be terminated in

Pagina 18

9. Connect the enclosure’s safety cord clip to the tab in the camera drive to allow the drive to hang from the enclosure. Refer to Figure 7 for loc

Pagina 19 - Installation

Optional Independent Support If it is necessary to provide independent support for the SurveyorVFT, other than the ceiling material, order the optio

Pagina 20

Indoor Pendant Model The indoor pendant model mounts on a Vicon mount (refer to the table in the Introduction section) or a 1.5-inch vertical pipe w

Pagina 21

Figure 12 Unlatching the Customer Interface Board b) Refer to Wiring section and Tables 2A, 2B and 2C to make all connections to terminal block TB

Pagina 22 - Detailed Installation

Figure 13 Safety Cord Installation 12. Lift the SurveyorVFT camera drive up to the housing and attach the housing’s safety cord clip to the camer

Pagina 23

Important Safeguards – Outdoor Use GRAPHIC SYMBOL EXPLANATION The lightening bolt symbol alerts the user to the presence of dangerous voltage that ma

Pagina 24

Outdoor Pendant Model The Outdoor Pendant model mounts on a Vicon mount (refer to the table in the Introduction section) or a 1.5-inch vertical pip

Pagina 25

Alternate Mounting Configuration b) Refer to Wiring section and Table 2 to make all connections to terminal block TB1 (power), TB2 (alarms), TB3

Pagina 26 - Optional Independent Support

13. Install the provided optional heater duct (recommended to minimize condensation problems). It is used to redirect warm air onto the lower dome s

Pagina 27 - Indoor Pendant Model

15. Align the tabs on the camera drive with the slots in the housing, matching up the two arrows on the camera drive and the housing. Figure 17 In

Pagina 28

Figure 18 Outdoor Lower Dome Installation 26 • 4BInstallation XX134-08-01 Rev 209 SurveyorVFT Camera Dome System

Pagina 29

Wiring Wiring is done with runs of cable for power, video and control. Optional wiring can be installed for the relay output and alarm inputs. All ca

Pagina 30 - Outdoor Pendant Model

Figure 19 Customer Interface Board Connections 28 • 5BWiring XX134-08-01 Rev 209 SurveyorVFT Camera Dome System

Pagina 31

Typical Relay and Alarm Connections Alarm input and relay output type signals are also carried on individually-shielded twisted-pair cable sets. The

Pagina 32

Installing the Cables WARNING: Disable the AC power to prevent installer injury and damage to the unit. Cables are installed using 2 different metho

Pagina 33

For an Indoor or Outdoor Pendant Model Installation Refer to Figure 19 customer interface boards for indoor or outdoor pendant model mount cable ins

Pagina 35

CONNECTOR/PIN NUMBERCONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAMEBNC (female)VIDEO (J1)J1VIDEOVideo outputAMP HeaderJ2J2 (Fiber Optic board)* Video/

Pagina 36 - Figure 19

CONNECTOR/PIN NUMBERCONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAMETERMINAL BLOCKVIDEO NVT (TB4)TB4-1UTP +Unshielded twisted pair +TB4-2UTP -Unshielde

Pagina 37

CONNECTOR/PIN NUMBERCONNECTOR TYPE CONNECTOR/PIN LABEL SIGNAL NAMETERMINAL BLOCKPOWER (TB1)TB1-1HHotTB1-2NNeutralTERMINAL BLOCKALARM (TB2)TB2-1ALARM

Pagina 38 - Installing the Cables

Installation Configurations There are two types of installation configurations for coaxial, twisted-pair and fiber-optic domes, daisy-chain or star,

Pagina 39

Installing the Flash Upgrade and PC Direct Control It is possible to upgrade software for the SurveyorVFT through a PC and to control the SurveyorVFT

Pagina 40

Standalone Configuration System Star Configuration When multiple domes are connected in a star configuration, using a V1400X-IDL, the RS-232/RS-42

Pagina 41 - Table 2B

Star Configuration System After the physical connections are made, insert the software disk and select the appropriate program, Flash Upgrade Util

Pagina 42 - Table 2C

Configuration The SurveyorVFT must be configured for its address and mode and termination setting when using RS-422/RS-485 protocol. The address and

Pagina 43 - Installation Configurations

NOTE: DIP switches labeled ON or CLOSED and OFF or OPEN have the same meaning. Figure 23 DIP Switch Label Competitive Protocol Settings, SW2 Swi

Pagina 44 - Standalone Configuration

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 6BConfiguration • 41 DIP Switch 1 (SW1) Address (Pilot/NOVA/VPS Mode) SWITCHES SWITCHES SWITCH

Pagina 45 - Star Configuration

FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNIN

Pagina 46

Setting the End-of-Line Jumpers JP1, JP2 & JP3 for RS-485 Protocol Operation Figure 24 End-of-Line Jumper Location This section defines settin

Pagina 47 - Configuration

When adding a SurveyorVFT IP Camera to the ViconNet network, the following items must be considered: • The number of cameras on a switch with respe

Pagina 48

Setup TAB Note: Since the Setup configuration affects the entire installation process, it MUST be configured first. In the Setup TAB, 3 fields are d

Pagina 49 - #12345678#12345678#12345678

4. Press the Select button on the lower section of the screen. Note: You MUST click the Select button to add the unit to the list; verify that it is

Pagina 50 - Operation

Install TAB The Install TAB allows the user to install/upgrade newer versions. Choose the correct version and click Install to send to the selected u

Pagina 51 - Using the VNSetup Utility

Advanced TAB The Advanced TAB functionalities allow the user to handle unexpected events on a specific remote unit when they occur. When a problem o

Pagina 52 - Select TAB

Custom TAB The Custom TAB allows setup of the VOX settings. The VOX mechanism allows setting the IP device so that it will not transmit audio if the

Pagina 53 - Unit TAB

After the SurveyorVFT has been configured for ViconNet, upon another boot up (or preset 97), the opening screen will display (see below). This screen

Pagina 54 - Info Tab

ViconNet Configuration After the camera dome has been setup with the proper IP address, configuration features from a remote workstation, server or r

Pagina 55 - Advanced TAB

Uninstalling the SurveyorVFT The SurveyorVFT camera drive can be easily uninstalled by simply pushing in the tabs to release the camera drive from th

Pagina 57

Operation Following the complete installation and setup of the SurveyorVFT, it is necessary to perform initial power-up testing and verify proper ope

Pagina 58 - ViconNet Configuration

Verifying Proper Operation Set up a remote keypad via RS-422/485 or a Pilot/NOVA/VPS CPU via RS-422/485 or Vicoax protocol to the SurveyorVFT. Power-

Pagina 59 - Uninstalling the SurveyorVFT

54 • 8BOperation XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 2. Press the PP ENTER key; the PRESET LED displays a blinking 0. 3. Press

Pagina 60

Competitive Protocols The SurveyorVFT Camera Dome can be operated by a number of competitive protocols. The tables below outline how to use the funct

Pagina 61 - Verifying Proper Operation

Pelco Function Keypress Function KeypressEnter Menu95, Preset Set (Program Label screen appears), F2 Set Transmit Polarity93, Preset Set (Program La

Pagina 62 - Troubleshooting

Sensormatic Function Keypress Function KeypressEnter MenuPress and hold IRIS Open, press and hold Focus (near or far), press Zoom OutSet Transmit Po

Pagina 63 - Competitive Protocols

Kalatel Function Keypress Function KeypressEnter MenuPress Set until "Enter Programming Code" appears. Enter Access Code 951followed by SE

Pagina 64

Ultrak When changing SurveyorVFT software addresses, the keypad may not respond to all 256 addresses. The workaround is to go to Ultrak KEGS Setup

Pagina 65

60 • 9BCompetitive Protocols XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Panasonic Function Keypress Function KeypressEnter MenuPress and

Pagina 66 - Function Ke

Philips Function Keypress Function KeypressEnter MenuUse On-46-Enter shortcut to enter Dome menu. Use Focus Far button to select and save options. U

Pagina 67

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System • iii Contents INTRODUCTION...

Pagina 68

62 • 9BCompetitive Protocols XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Cohu Function Keypress Function KeypressEnter MenuTo launch Dome

Pagina 69

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 10BMaintenance • 63 Maintenance The SurveyorVFT requires no scheduled maintenance; however, the

Pagina 70

64 • 11BShipping Instructions XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Shipping Instructions e FarehamUnited Kingdom Use the following

Pagina 71 - Maintenance

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 12BReference • 65 Reference Coaxial Cable Recommendations Caution: Careful selection of proper

Pagina 72 - Shipping Instructions

66 • 12BReference XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Twisted-Pair Cable CAUTION: Careful selection of the proper cable is essenti

Pagina 73 - Reference

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 12BReference • 67 Network Cable Caution: Careful selection of proper cable is essential to obt

Pagina 74 - 1.5-inch Pipe Designation

68 • 13BTechnical Information XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Technical Information with electronic control. Units available i

Pagina 75 - Network Cable

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 13BTechnical Information • 69 Real time clock allows scheduling of up to 64 events, including

Pagina 76 - Technical Information

70 • 13BTechnical Information XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Distance ft (m) Indoor Outdoor 24 V 28 VAC 24 VAC AC 28 VAC Wi

Pagina 77

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 13BTechnical Information • 71 Table 5: Camera/Lens Specifications Model Numbers SVFT-C22, SVFT

Pagina 78

For RS-422/485 Mode: ... 39 F

Pagina 79

72 • 13BTechnical Information XX134-08-01 Rev 209 SurveyorVFT Camera Dome System Model Numbers SVFT-C22CA, SVFT-P22CA, SVFT-W22CA/ SVFT-C22CA

Pagina 80

XX134-08-01 Rev 209 SurveyorVFT Camera Dome System 14BVicon Standard Equipment Warranty • 73 Vicon Standard Equipmeicon Industries Inc. (the “Comp

Pagina 81 - Vicon Standard Equipme

Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2

Pagina 82 - Germany

Introduction The information in this manual covers the installation, configuration and operation of the SurveyorVFT™ Camera Dome. This system should

Comentarios a estos manuales

Sin comentarios