XX112-36-00 Rev 909 Kollector Hybrid Network Digital Video Recorder Configuring the ViconNet System 67
7. Repeat steps 4 through 6 on the site handling the backup Nucleus (optional).
8. Ensure that the backup Nucleus is working properly by exiting to the operating system on the site acting
as the master Nucleus. The backup Nucleus name should now appear in the top-left corner of all sites
instead of the master Nucleus name (for example, in place of Workstation-1, the name should now
read Workstation-2).
9. Log back into the master Nucleus. Its name should now reappear in the top-left corner of all sites
instead of the backup Nucleus name.
Configuring a Site to Work with an Existing Network Nucleus
To configure a site to work with an existing network:
1. Follow steps 1 through 3 in Step 1: Setting the Sites' IP Addresses, page 63.
2. Deselect the This Site is the Master Nucleus checkbox.
3. Select the Nucleus IP radio button and then enter the IP address of the site handling the master
Nucleus.
4. Click
. The application will reboot.
Configuring the Network Setup for a Standalone System
The ViconNet system enables you to configure a transmitter as the master Nucleus in the system without
using a backup Nucleus, if required. When performing this configuration, the system automatically detects
the local device IP address and DNS information.
On a standalone system – where only a single recorder is involved, with no Workstations or other Kollectors
connected to it (that is, no other sites are connected to it) – the Nucleus can be configured locally. However,
it is recommended that the Nucleus be configured on a separate system whenever possible.
NOTE: If the Nucleus goes down, any device that uses that master Nucleus will automatically shift to local
operation mode. This means that it will use the latest Nucleus configuration from before losing the
Nucleus and will keep operating without a Nucleus.
To configure the network setup for a standalone system:
1. Go to the site you want to setup and follow steps 1 through 3 in Step 1: Setting the Sites' IP Addresses,
page 63.
NOTE: In cases where the Nucleus is not running on the local device, the IP address and the DNS
must be typed in manually. As this is a standalone system, you do not need to enter a backup
IP address or DNS.
2. Click . A notification message is displayed, prompting you to restart the currently connected