Chapter 14: Central Management Utility
Step 3. Select the Auto Discovery option from the Module Name drop-
down box. (See Figure 14-3)
Figure 14-3: Auto Discovery
Step 4. Define the IP scan range to search the network. Click Finish.
Step 5. Double-click the ON/OFF switch.
The Root Agent will automatically scan the IP range for available
subsystems on the network.
Step 6. Check the scan results in RootAgent Setting.
IMPORTANT!
The Auto Discovery Module only supports the Firmware versions listed
below.
FW 3.42H03 or later - Fibre to SATA
FW 3.42J09 or later - SCSI to SATA
FW3.42R01 or later - Fibre to Fibre
Auto Discovery cannot detect a subsystem if the firmware version is
older then those listed above. However, you can still manually provide
the subsystem’s Agent IP.
Setting Up the Utility 14-3