GPIO and Remote Connections in MX Ultranet and MX Sync
Vicon MX Hardware System Reference B-13
StopOffset Section
The syntax for the StopOffset section is:
<StopOffset Frames="" MicroSeconds=""/>
where:
Important
If you specify both Frames and MicroSeconds, the two values are added
together to determine the offset.
PulseWidth Section
The syntax for the PulseWidth section is:
<PulseWidth Frames="" MicroSeconds=""/>
where:
Important
If you specify both Frames and MicroSeconds, the two values are added
together to determine the offset.
StopOffset specifies the delay between the MX system receiving
the stop command and the MX Ultranet terminating
the synchronization signal to the GPO device as either
one or the sum of both the following:
Frames The number of frames by which to
delay terminating the signal after the
event specified in the StopEvent
section.
MicroSeconds The number of microseconds by
which to delay terminating the signal
after the event specified in the
StopEvent section.
PulseWidth specifies the fixed duration of the synchronization
pulse signal as either one or the sum of both the
following:
Frames The number of frames the pulse
signal is to last.
MicroSeconds The number of microseconds the
pulse signal is to last.
MXhardware_Reference.book Page 13 Monday, April 30, 2007 1:56 PM