GPIO and Remote Connections in MX Ultranet and MX Sync
B-16 Vicon MX Hardware System Reference
Table B-5 shows the TTL settings to which your external switch must
pull the Remote input pins in order to trigger the remote capture.
Remote Output Status Events
Table B-6 shows the status events output by the remote control after
the remote capture has been triggered (where High=5V and
Low=0V). You can configure other devices in your system to read
these events and respond accordingly.
Table B-5: Remote input controls
Input Control Action
Pin 3 Pin 5
High High Idle (normal system setting)
Low High Start capture at next video frame
High Low Stop capture at next video frame
Low Low Undefined (do not use)
Table B-6: Remote output status
Output Status Vicon System Event
Pin 7 Pin 14
Low Low Idle (no capture in progress)
High Low Armed (prepared for capture)
Low High Paused
High High Capturing